Output Explorer

Every prompt in the paper, and what each model wrote back.

Answer a question about a scanned page from its OCR text. Scored by exact match and ANLS against the accepted answers.

13 of 5,330 prompts

Nearby prompts. All 5,330 DocVQA prompts

PromptDocVQA · pagezjph0227_4.png

What type of analysis is this?

OCR text of the page · 1,264 characters; the scanned image itself is not published
FORM 443 2M 6-64-PADS 100
WATER ANALYSIS
Mitehall
...........Factory
April.. 1.19_66.
Kind of Water :
Main Supply Tank
Description of Sample :
Average Sample for Campaign 1965-66
Source of Water :
Seepage and Runoff Water taken from Dry Spotted Tail Creek; about 1/4
mile Northwest of factory
ANALYSIS
HYPOTHETICAL COMBINATIONS
Parts Per Million
Parts Per Million
Silica
SiO2
82.80
Silica
SiO
82.80
Iron
Fe
1.82
Sodium Chloride
NaCl
36.93
Calcium
Ca
67.11
Sodium Sulfate
NazSO4
Sodium Carbonate
NazCOs
177.43
Magnesium
Mg
20.71
Sodium
Na
71.98
Sodium Phosphate
Nag PO4
Chlorine
C1
22.40
Magnesium Chloride
MgCl2
Sulfuric Acid
SO4
174.89
Magnesium Sulfate
MgSO
68.81
Carbonic Acid
CO3
PO4
119.24
Magnesium Carbonate MgCO3
23.61
Phosphoric Acid
Magnesium Phosphate Mg3(PO4)2
Calcium Sulfate
Ca SO4
Calcium Carbonate
CaCO3
Calcium Phosphate
Cag (PO4)2
167.59
Ferrous Carbonate
FeCO3
3.78
Ferrous Phosphate
Fe3 (PO4)2
560.95
560.95
Organic and Volatile (by difference)
22.85
Organic and Volatile (by difference)
22.85
TOTAL DISSOLVED SOLIDS AT 105. C
583.80
TOTAL DISSOLVED SOLIDS AT 105. C 583.80
PH
8.5
COPIES TO
General Chemist
Dist. Supt.
District Engineer
Superintendent
Laboratory
- 2 -
Chief Chemist.
Source: https://www.industrydocuments.ucsf.edu/docs/zjph0227
System prompt · identical for every setup
Answer the question using only the OCR text from a single document page. Return only the answer, with no explanation. Preserve the answer wording from the OCR text when possible.
Expected answer
Water analysis
Models
4 of 4 columns · click a model to add or remove it

Ours

Exact match

WATER ANALYSIS

14 characters5 tokens

Aux 2015

Wrong

FORM 443 2M 6-64-PADS 100 WATER ANALYSIS Mitehall ........... Factory April.. 1.19_66. Kind of Water : Main Supply Tank Description of Sample : Average Sample for Campaign 1

173 characters64 tokens

PiT-FT 2015

Wrong

Empty response.

0 characters

ChronoGPT 2015

Wrong

Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis Water Analysis